EOTech Target Pointer Illuminator Aiming Light User Manual

Page 84

Advertising
background image

3-2

3.1.4 Laser Ports. The laser ports should be inspected for
foreign material. Remove any large particles or loose dirt
using air or a soft cloth. Fine cleaning should be performed
using Lens Tissue. Clean water, alcohol, or general purpose
window cleaner may be used to remove stubborn stains.
Avoid using excessive force as this may scratch the lenses.

3.1.5 Remote Jack. The Remote Jack should be inspected
for corrosion, dirt and damage. Gently remove any large
particles of foreign matter and clean with alcohol and a
cotton swab.

3.1.6 AN/PEQ-2A Housing. To clean the AN/PEQ-2A
housing, rinse with water or mild soap and water and then
wipe dry with a soft cloth. Clean around switches, adjusters,
and attachment points with a cotton swab.

3.1.7 Removal / Replacement of Safety Block. A .050 hex
key is required to perform this procedure.

a. Using a .050 hex key, turn the Safety Block

mounting screw counterclockwise to loosen.
Continue turning until the Safety Block comes free of
the AN/PEQ-2A housing.

b. Position the Safety Block in the desired position (i.e.,

Tactical, Training) with either the blue or black side
facing up (see Figures 3-1 and 3-2).

c. Using a .050 hex key, turn the Safety Block

mounting screw clockwise to tighten.