EOTech Target Pointer Illuminator Aiming Light User Manual

Page 86

Advertising
background image

3-4

3.2 TROUBLESHOOTING PROCEDURES
The procedures below will help the operator correct some of
the basic problems that may arise with the AN/PEQ-2A. If
the equipment malfunction is not listed, or the actions listed
do not correct the fault, refer to Section II for additional
guidance.

a. Laser(s) fail to come on when activated.

(1) Verify Mode Selector is not in Position 0 (O).
(2) Verify that the battery is properly installed per

paragraph 2.2.2.

(3) Ensure that the Lens Caps and laser ports are

not obscured by mud or dirt.

(4) Replace existing battery with fresh battery.

b. Laser(s) appear weak.

(1) Ensure that the Lens Caps and laser ports are

not obscured by mud or dirt.

(2) Replace existing battery with fresh battery.
(3) Ensure Neutral Density Lens Cap, Pattern

Generator and/or Illuminator Diffuser Lens Cap
are not installed in front of laser ports.

(4) Check to see if the laser ports are scratched or

pitted.


3.3 CORRECTIVE MAINTENANCE
The AN/PEQ-2A has no internal parts or assemblies
replaceable at the operator level.

a. Replacement of Battery Cap Lanyard. No supplies
or tools are required to perform this procedure.

(1) Remove

Battery

Cap.

(2) Pull lanyard over Battery Compartment threads.

Advertising