2.4.3 Boresighting Procedures. The AN/PEQ-2A
incorporates a unique zero preset feature which enables the
aim and illumination beams to be nearly zeroed when initially
attached to the weapon.

To establish this zero preset, rotate

each adjuster to its full clockwise end of travel, then rotate
them back approximately 5.5 turns to align the white dot on
the adjuster with the hole on the adjuster cover.

CAUTION

..

Do not force the adjusters beyond their end of
travel.

The AN/PEQ-2A may also be boresighted to the host
weapon using a Laser Borelight System (LBS). Table 2-7
provides 10m Target Offsets for this purpose. Refer to the
latest version of the LBS Operator Manual for boresighting
procedures.

After establishing the zero preset or boresighting the
AN/PEQ-2A / weapon combination, the AN/PEQ-2A may be
zeroed to the weapon via live fire at a 25-meter range as
described in paragraph 2.4.4. Table 2-7 provides target
offsets that must be applied to the 25-meter zeroing target.

The following abbreviations and their definitions apply solely
to the last two columns of Table 2-7:

L

Left

R

Right

U

Up

D

Down

F

Flood

(Illumination)

Laser

IR

IR (Infrared) Aim Laser