Anritsu Site Master S331D User Manual
Site master, Programming manual
Advertising
This manual is related to the following products:
Table of contents
Document Outline
- Cover Page
- Table of Contents
- Programming Overview 1
- Control Byte Summary 3
- Control Byte Descriptions 7
- Setup System Œ Control Byte #1 (01h) 7
- Set Site Master VNA Frequency Œ Control Byte #2 (02h) 7
- Select Measurement Mode Œ Control Byte #3 (03h) 8
- Set Site Master VNA Scale Œ Control Byte #4 (04h) 8
- Set Site Master VNA Marker Œ Control Byte #5 (05h) 9
- Set Site Master VNA Single Limit Œ Control Byte #6 (06h) 9
- Set DTF Parameter Œ Control Byte #7 (07h) 10
- Set Time/Date Œ Control Byte #8 (08h) 11
- Set Reference Number Œ Control Byte #9 (09h) 11
- Serial Port Echo On/Off Œ Control Byte #10 (0Ah) 11
- Site Master VNA Single Sweep Mode On/Off Œ Control Byte #11 (0Bh) 12
- Watch-Dog Timer On/Off Œ Control Byte #12 (0Ch) 12
- Sequence Site Master Calibration Œ Control Byte #13 (0Dh) 13
- Set Site Master Data Points Œ Control Byte #14 (0Eh) 13
- Set Site Master Calibration Mode Œ Control Byte #15 (0Fh) 13
- Store Sweep Trace Œ Control Byte #16 (10h) 14
- Recall Sweep Trace Œ Control Byte #17 (11h) 14
- Save System Setup Œ Control Byte #18 (12h) 20
- Recall System Setup Œ Control Byte #19 (13h) 21
- Query System Status Œ Control Byte #20 (14h) 21
- Trigger Self-Test Œ Control Byte #21 (15h) 28
- Read Fail Counter Œ Control Byte #22 (16h) 29
- Query Trace Names Œ Control Byte #24 (18h) 29
- Delete Sweep Trace Œ Control Byte #25 (19h) 29
- Upload SPA Sweep Trace Œ Control Byte #26 (1Ah) 30
- Query Sweep Memory Œ Control Byte #27 (1Bh) 33
- Upload Site Master VNA Sweep Trace Œ Control Byte #28 (1Ch) 33
- Query System Status Œ Control Byte #29 (1Dh) 36
- Select Printer Type Œ Control Byte #30 (1Eh) 48
- Select DTF Windowing Œ Control Byte #31 (1Fh) 49
- Set Site Master VNA Trace Math Œ Control Byte #32 (20h) 49
- Recall Sweep Trace Œ Control Byte #33 (21h) 49
- Set Site Master VNA Trace Overlay Œ Control Byte #34 (22h) 61
- Set SPA A/B Trace Œ Control Byte #35 (23h) 61
- Upload Sweep Trace Œ Control Byte #36 (24h) 62
- Get Options Œ Control Byte #37 (25h) 71
- Query Power Level Œ Control Byte #39 (27h) (Option 29 only) 72
- Set Power Meter Units Œ Control Byte #40 (28h) (Option 29 only) 72
- Power Meter Relative Mode On/Off Œ Control Byte #41 (29h) (Option 29 only) 73
- Power Meter Offset Mode On/Off Œ Control Byte #42 (2Ah) (Option 29 only) 73
- Power Meter Zero Mode On/Off Œ Control Byte #43 (2Bh) (Option 29 only) 73
- Power Meter RMS Averaging On/Off Œ Control Byte #44 (2Ch) (Option 29 only) 73
- Power Meter Center Freq and Span Setup Œ Control Byte #45 (2Dh) (Option 29 only) 74
- Trigger Sweep Œ Control Byte #48 (30h) 74
- Trigger Sweep Œ Control Word (AA30h) 74
- Check Battery Status Œ Control Byte #50 (32h) 74
- Set SPA Minimum Sweep Time - Control Byte #53 (35h) 75
- Set Trigger Position - Control Byte #54 (36h) 75
- Set Video Trigger Level - Control Byte #55 (37h) 75
- Automatically Save Runtime Setup Œ Control Byte #64 (40h) 76
- Enter Remote Mode Œ Control Byte #69 (45h) 76
- Enter Remote Mode Immediately Œ Control Byte #70 (46h) 76
- Write Custom Cable Œ Control Byte #80 (50h) 77
- Recall Custom Cable Œ Control Byte #81 (51h) 77
- Write Antenna Œ Control Byte #82 (52h) 78
- Recall Antenna Œ Control Byte #83 (53h) 78
- Set Field Strength Measurement Œ Control Byte #84 (54h) 79
- Set Channel Power Œ Control Byte #85 (55h) 79
- Read Channel Power Œ Control Byte #86 (56h) 80
- Set Adjacent Channel Power Ratio (ACPR) Œ Control Byte #87 (57h) 80
- Read Adjacent Channel Power Ratio (ACPR) Œ Control Byte #88 (58h) 80
- Read Signal Standard Name Œ Control Byte #89 (59h) 81
- Measure OCC BW % of Power Œ Control Byte #96 (60h) 81
- Measure OCC BW dB Down Œ Control Byte #97 (61h) 82
- Set Bias Tee Function - Control Byte #98 (62h) (Option 10 only) 82
- Set Spectrum Analyzer Start/Stop Frequency Œ Control Byte #99 (63h) 83
- Set Spectrum Analyzer Center Freq./Span Œ Control Byte #100 (64h) 83
- Set Spectrum Analyzer Scale Œ Control Byte #101 (65h) 83
- Set Spectrum Analyzer Marker Œ Control Byte #102 (66h) 84
- Set Spectrum Analyzer Single Limit Œ Control Byte #103 (67h) 84
- Set Spectrum Analyzer Peak Hold Œ Control Byte #105 (69h) 85
- Set Spectrum Analyzer Resolution Bandwidth Œ Control Byte #106 (6Ah) 85
- Set Spectrum Analyzer Video Bandwidth Œ Control Byte #107 (6Bh) 85
- Set Spectrum Analyzer Sweep Mode Œ Control Byte #108 (6Ch) 86
- Set Spectrum Analyzer Marker to Peak Œ Control Byte #109 (6Dh) 86
- Set Spectrum Analyzer Marker to Center Œ Control Byte #110 (6Eh) 86
- Set Spectrum Analyzer Attenuation Œ Control Byte #111 (6Fh) 87
- Set Site Master VNA Segmented Limit Lines Œ Control Byte #112 (70h) 87
- Set Spectrum Analyzer Multiple Limit Œ Control Byte #113 (71h) 88
- Set Return Spectrum Analyzer Sweep Time Œ Control Byte #114 (72h) 89
- Set Reference Level Offset Œ Control Byte #115 (73h) 89
- Read Marker Value Œ Control Byte #117 (75h) 90
- Set Sweep Averaging Œ Control Byte #118 (76h) 90
- Field InstaCal Œ Control Byte #120 (78h) 90
- Read InstaCal Module ASCII Serial Number Œ Control Byte #124 (7Ch) 91
- Set Site Master Marker (Peak/Valley) Œ Control Byte #129 (81h) 91
- Set / Reset Spectrum Analyzer External Reference Œ Control Byte #133 (85h) 91
- Check Spectrum Analyzer External Reference Œ Control Byte #134 (86h) 92
- Set SPA Preamp State (On/Off/Auto) Œ Control Byte #136 (88h) 92
- Set Spectrum Analyzer Units Œ Control Byte #140 (8Ch) 92
- Set Spectrum Analyzer Resolution Bandwidth Œ Control Byte #141 (8Dh) 93
- Set Spectrum Analyzer Video Bandwidth Œ Control Byte #142 (8Eh) 93
- Set Spectrum Analyzer Attenuation Œ Control Byte #143 (8Fh) 93
- Set AM/FM Demodulation Œ Control Byte #145 (91h) 94
- Set Baud Rate Œ Control Byte #197 (C5h) 95
- Set Language Œ Control Byte #198 (C6h) 95
- Query Time Œ Control Byte #208 (D0h) 95
- Read ASCII Serial Number Œ Control Byte #225 (E1h) 96
- Exit Remote Mode Œ Control Byte #255 (FFh) 96
- Set T1 Transmission Level Œ Control Word (A001h) (Option 50 only) 96
- Set T1/E1 Clock Source Œ Control Word (A002h) (Option 50 only) 96
- Set T1/E1 Pattern Œ Control Word (A003h) (Option 50 only) 97
- Set T1/E1 Error Insert Type/Value Œ Control Word (A004h) (Option 50 only) 97
- Set T1/E1 Framing Mode Œ Control Word (A005h) (Option 50 only) 98
- Start and Stop T1/E1 Measurement Œ Control Word (A006h) (Option 50 only) 98
- Insert Error for T1/E1 Measurement Œ Control Word (A007h) (Option 50 only) 98
- Get T1/E1 Pattern Œ Control Word (A008h) (Option 50 only) 98
- Get T1/E1 Frame Sync Status Œ Control Word (A009h) (Option 50 only) 99
- Get T1/E1 Pattern Sync Status Œ Control Word (A00Ah) (Option 50 only) 99
- Get T1/E1 Carrier Status Œ Control Word (A00Bh) (Option 50 only) 99
- Get T1/E1 Error Type and Number Œ Control Word (A00Ch) (Option 50 only) 99
- Set T1/E1 Line Coding Options Œ Control Word (A00Dh) (Option 50 only) 100
- Set E1 Impedance Options Œ Control Word (A00Eh) (Option 50 only) 100
- Read T1/E1 Volts Peak-to-Peak Œ Control Word (A00Fh) (Option 50 only) 100
- Set T1/E1 Receive Input Configuration Options - Control Word (A013h) (Option 50 only) 101
- Set T1/E1 Measurement Duration - Control Word (A014h) (Option 50 only) 101
- Set T1/E1 Data Logging - Control Word (A015h) (Option 50 only) 101
- Read T1/E1 dBdsx - Control Word (A016h) (Option 50 only) 102
- Read T1/E1 Frequency - Control Word (A017h) (Option 50 only) 102
- Read T1/E1 Frequency Cal - Control Word (A018h) (Option 50 only) 102
- Set T1/E1 Frequency Cal - Control Word (A019h) (Option 50 only) 102
- Select SPA/Power Meter Signal Standard - Control Word (A103h) 103
- Select SPA/Power Meter Channel - Control Word (A104h) 103
- Read External Module Name Œ Control Word (A201h) (Option 6 only) 103
- Read External Module Serial Number Œ Control Word (A202h) (Option 6 only) 104
- Read External Module Frequency Range Œ Control Word (A203h) (Option 6 only) 104
- Read Module Fail Counter Œ Control Word (A204h) (Option 6 only) 104
- Clear Module Fail Counter Œ Control Word (A205h) (Option 6 only) 105
- Remote Self Test - Control Word (AA15h) 105
- Programming Examples 108
- Parameter Definitions 119
- Spectrum Analyzer Signal Standards 120
- VNA Signal Standards 123