Section 2. Automotive Testing

The digital multimeter is a very useful tool for

trouble-shooting automotive electrical

systems. This section describes how to use

the digital multimeter to test the starting and

charging system, ignition system, fuel system,

and engine sensors. The digital multimeter

can also be used for general testing of fuses,

switches, solenoids, and relays.

General Testing

The digital multimeter can be used to test

fuses, switches, solenoids, and relays.

Testing Fuses

This test checks to see if a fuse is blown.

To test Fuses (see Fig. 13):

• Fuse is blown if display reading indicates

an overrange condition. (see Setting the

Range on page 6)

NOTE: Always replace blown fuses with

same type and rating.

Testing Switches

This test checks to see if a switch “Opens”

and “Closes” properly.

To test Switches (see Fig. 14):

1. Insert BLACK test lead into the COM

test lead jack.

2. Insert RED test lead into the test lead

jack.

1. Insert BLACK test lead into the COM

test lead jack.

2. Insert RED test lead into the

V

test

lead jack.

3. Turn multimeter rotary switch to 200

range.

4. Touch RED and BLACK test leads

together and view reading on display.

Display should read typically 0.2

to 1.5

.

If display reading was greater than 1.5

,

check both ends of test leads for bad

connections. If bad connections are found,

replace test leads.

5. Connect RED and BLACK test leads to

opposite ends of fuse.

View reading on display:

• Fuse is good if display reading is less

than 10

.

3. Turn multimeter rotary switch to 200

range.

4. Touch RED and BLACK test leads

together and view reading on display.

Display should read typically 0.2

to 1.5

.

If display reading was greater than 1.5

,

check both ends of test leads for bad

connections. If bad connections are found,

replace test leads.

5. Connect BLACK test lead to one side of

switch.

6. Connect RED test lead to other side of

switch.

Fig. 13

Fuse

Red

Black

Fig. 14

Typical

"Push"

Button

Switch

Red

Black

Advertising