8. Operate Sensor.

• Start engine and let idle.

• Display reading should...

– increase in voltage from Key On

Engine OFF for DC type MAF sensors.

– increase in RPM from Key On Engine

OFF for Low Frequency type MAF

sensors.

• Rev Engine.

• Display reading should...

– increase in voltage from Idle for DC

type MAF sensors.

– increase in RPM from Idle for Low

Frequency type MAF sensors.

• Refer to vehicle service manual for

charts relating MAF sensor voltage or

frequency(RPM) to increasing air flow.

• Use equation above for Frequency and

RPM conversions.

9. Test Results.

Good Sensor:

• Sensor output voltage or frequency

(RPM) are within manufacturers

specifications at Key ON Engine OFF.

• Sensor output voltage or frequency

(RPM) increase with increasing air flow.

Bad Sensor:

• Sensor output voltage or frequency

(RPM) are not within manufacturers

specifications at Key ON Engine OFF.

• Sensor output voltage or frequency

(RPM) do not change with increasing air

flow.

Electrical Specifications

DC Volts
Range: 2V, 20V, 200V
Accuracy : ±(1.0% rdg + 2 dgts)

AC Volts
Range: 750V
Accuracy: ±(0.75% rdg + 2 dgts)

Resistance
Range:

200

, 2K

, 20K

, 200K

, 2M

, 20M

Accuracy: ±(0.75% rdg + 2 dgts)

Dwell
Range: 4CYL, 5CYL, 6CYL, 8CYL
Accuracy: ±(3.0% rdg + 5 dgts)

RPM
Range: 4CYL, 5CYL, 6CYL, 8CYL
Accuracy: ±(3.0% rdg + 5 dgts)