Functions and Display Definitions

(Refer to Digital Multimeter illustration on facing page)

1. ROTARY SWITCH

Switch is rotated to turn multimeter ON/

OFF and select a function.

2. RPM X 10

This Function is used for measuring

engine speed (RPM).

3. DWELL

This Function is used for measuring

DWELL on distributor ignition systems,

and solenoids.

4. DIODE CHECK

This Function is used to check whether a

diode is good or bad.

5. TEST LEAD JACKS

BLACK Test Lead is always inserted in the

COM test lead jack.

RED Test Lead is always inserted in the

or

V

test lead jack.

Always connect TEST LEADS to the

multimeter before connecting them to

the circuit under test!!

6. OHMS

This Function is used for measuring the

resistance of a component in an electrical

circuit in the range of 0.1

to 20M

. (

is

the electrical symbol for Ohms)

7. DC VOLTS

This Function is used for measuring DC

(Direct Current) Voltages in the range of 0

to 200V.

8. AC VOLTS

This Function is used for measuring AC

(Alternating Current) Voltages in the range

of 0 to 750V.

9. DISPLAY

Used to display all measurements and

multimeter information.

Low Battery – If “LO BAT” appears in the

upper left corner of the display, then

replace the internal 9V

battery. (see Battery

Replacement on page 7.)

Overrange Indication – If “1”

or “-1” appears on the left

side of the display, then the

multimeter is set to a range

that is too small for the

present measurement being

taken. Increase the range

until this disappears. If it

does not disappear after all the ranges for

a particular function have been tried, then

the value being measured is too large for

the multimeter to measure. (see Setting

the Range on page 6.)

Zero Adjustment

The multimeter will automatically zero on the

Volts, Amps, and RPM functions.

Automatic Polarity Sensing

The multimeter display will show a minus (-)

sign on the DC Volts and DC Amps functions

when test lead hook-up is reversed.