SWR (Return Loss) and Cable Loss Measurement

The following frequency domain measurement is an example of a Standing Wave Ratio (or
Return Loss) and Cable Loss measurement made over a selectable frequency range. This
measurement example determines the quality and loss of the test port cable or device under
test.

Required Equipment

·

Site Master Model S251B

·

Precision N (m) Open/Short, Anritsu 22N50 and
Precision N (m) Load, Anritsu SM/PL

or

Precision N (m) Open/Short/Load, Anritsu OSLN50LF

·

N (m) - N (f) Test Port Extension Cable, Anritsu 15NNF50-1.5A

Device-Under-Test Specification

Procedure

Step 1. Press the

ON/OFF

key on the Site Master.

Selecting the Measurement Mode

Step 2. Press the

MODE

key.

Step 3. Use the Up/Down arrow key to scroll to

FREQ-SWR

or

FREQ-RETURN LOSS.

Step 4. Press the

ENTER

key to select Frequency SWR or Return Loss measurement

mode.

Selecting the Frequency Range

Step 5. Press the

FREQ/DIST

key.

Step 6. Press the

F1

soft key.

Step 7. Enter 6, 2, 5 using the key pad or the Up/Down arrow key.

Step 8. Press

ENTER

to set F1 to 625 MHz.

Step 9. Press the

F2

soft key.

Step 10. Enter 2, 5, 0, 0 using the keypad or the Up/Down arrow key.

Step 11. Press

ENTER

to set F2 to 2500 MHz.

Step 12. Check that the FREQ (MHz) scale in the display area indicates the new fre-

quency start and stop values (F1 = 625 MHz, F2 = 2500 MHz).

4-9

Chapter 4 Measurements

Type

Typical Loss @1.5m

V

g

Return Loss

SWR

15NNF50-1.5A

0.4 dB @ 625 MHz
0.5 dB @ 800 MHz
0.6 dB @ 1000 MHz
0.7 dB @ 1500 MHz
0.8 dB @ 2000 MHz
0.9 dB @ 2500 MHz