Electrical speci cations, Environmental speci cations, Table c-1 – Bay Technical Associates BayStack ARN Routers none User Manual

Page 122: Electrical specifications, Environmental specifications

Advertising
background image

Installing and Operating BayStack ARN Routers

C-2

114200 Rev. A

If you are installing your ARN in an electronic enclosure rack, make sure that the
rack meets the following specifications:

Heavy-duty steel construction

Electronic Industries Association (EIA) standard hole-spacing

Width of 19 in. (48.26 cm)

Depth of 24 in. (60.96 cm)

Electrical Specifications

Your installation site must meet the following power requirements:

Proximity to wall receptacle: within 6 ft (1.8 m) of the ARN

Voltage: 100 to 240 Vac

Amperage: 0.5 to 1.0 A

Table C-1

lists the wall outlet requirements.

Environmental Specifications

The environmental requirements of the ARN are as follows:

Altitude: 0 to 8,000 ft (0 to 2,438.4 m)

Humidity: 10% to 90%, noncondensing

Temperature: 32

°

F to 104

°

F (0

°

C to 40

°

C) stable

Table C-1.

ARN Wall Outlet Requirements

Country

Outlet

Voltage

United States/
Canada

National Electrical Manufacturers
Association (NEMA) 5-15P standard outlet

100 to 120 V

Any other country Your ARN distributor informs you of the

outlet you need.

200 to 240 V