2. Define a dialer chat script to place calls to the Router. The following command will work with almost

any V.34 modem, and must be entered on a single line:

[configure]
chat-script dial-v34 ABORT ERROR ABORT BUSY "" ATZ
OK "ATDT \T” TIMEOUT 60 CONNECT \c

The first two argument pairs indicate that if ERROR or BUSY messages are posted from the modem
side, dialing must be abandoned and restarted on the next triggering event. More such keywords can
be added.

The following are pairs of expect this and then send this:

\T—means insert the telephone number here.

\c—an end-of-script marker which means don’t send anything at this point.

" " sends a carriage return.

3. The line and interface definitions are similar to dial-in, but with the triggers for dialing out added:

[configure]
username xxxxx password yyyyy
line aux 0
login local
modem inout speed
38400 flowcontrol hardware
access-class 101 out
script dialer dial-v34
interface async 1
ip address a.a.a.a m.m.m.m
encapsulation ppp
async default ip address b.b.b.b
async mode interactive
ppp authentication chap
dialer in-band
dialer string 555-1234
dialer group 1

where a.a.a.a is the IP address number (Cisco), m.m.m.m is the mask number (Cisco), b.b.b.b is the IP
address (Router), and 555-l234 is the phone number (Router).

Cisco dialer script for Router

Because almost everything can be customized, the following Router dialer script is not guaranteed to
work for everyone. However, the following Router dialer script has been tested for dialing into a Cisco
system with the previous configuration (Step 3).