ASYNC ROUTER AR-P, AR-5, AND SYNC ROUTER USER’S MANUAL

24

Place the Sync Router on a shelf or tabletop and follow the steps. The step numbers coincide with

cables in the illustration.

1. Using either a 10BASE-T or AUI cable, connect your Ethernet LAN to the appropriate ( I 0BASE-T

or AUI) connector.

2. Locate the CSU/DSU you will be using. Use the cable provided (gray, 34-pin to 25-pin) to connect

the Router’s synchronous port to the V.35 port on the CSU/DSU. If you are using a CSU/DSU with a
non-V.35 interface, you must use an adapter (V.35 to non-V.35). Connect the synchronous port of the
CSU/DSU to the synchronous (digital) service line (RJ-45) provided by your telephone company.

3. Connect the modem0 (LINE) port to the desired telephone line. The modem can be used for

fallback, or to connect to a modem at a site that is not at the same site as the synchronous link.

4. Connect the power supply with the power cord. Do not start the Router at this time.

5. Proceed to Chapter 4.