ASYNC ROUTER AR-P, ASYNC ROUTER AR-5, SYNC ROUTER RELEASE NOTES

264

[20391] - ftp to Router using PCNFSpro windows ftp client does not show any files when you’ve
successfully logged in and use the dir command.

[20540] - To remove an IP firewall, use config firewall instead of config modify.

[20561] - Sometimes TCP port displays show negative numbers. Numbers above 2

15

(32768) will be

displayed as negative numbers.

[20682] - When a remote client connects, a syslog message appears to present the client’s password.
What is presented as the password (in the message) is the client‘s username. The password is never sent
to syslog.

PPP Issues

[20584] - The syslog on the Router shows an error message unknown ppp packet error when a Windows95
machine logs onto the Router using SecurID. Login is successful but an error message is displayed once.

[20585] - If the unit is configured with dialup modemX logprompt on and ppp modemX lcp local auth
none
then the client will see a login prompt. If using login/password when the prompt fails, the call will
be cleared, but if the client goes directly to PPP, no validation is performed. To perform validation, select
either CHAP or PAP. User must not set auth none. A later release issues a warning if the log prompt is set
to none.

IPX Mode Issues

[20271] - The ripfilter and sapfilter status messages do not display the maximum number of hops
allowed by the filter.

[20272] - When using the -h option of the ripfilter and sapfilter commands, the entries with hops
greater than the specified number are not deleted from the sap and route tables automatically. The
entries are only removed when the sap or route tables are flushed.

[20568] - SPX spoofing doesn’t work correctly with the Router, unless you install a patch on your
NetWare server.

workaround—The NetWare 4.1 Server contains a bug, which can be fixed by a patch named
WATDOGFX.NLM. This patch is available on Novell’s NETWIRE server (http://www.novell.com/) as
part of a larger patch kit named 410PT3.EXE (4.10 patch kit 3).

Remote Client Issues

[20588] - Remote Office Gold client fails to log in if the Router has login prompts enabled and clients
are not using it.

[20619] - If the baud rate on a Router’s analog modem is set too high (28.8K), then Remote Office will
not be able to log in (using tty mode). Lower the baud rate to allow the Remote Office client to log in.

[20682] - See previous write-up in TCP/IP Issues.

SecurID Issues

[20584] - See previous write-up in PPP Issues.

Windows 95 Issues

[20584] - See previous write-up in PPP Issues.

[20593] - Windows 95 clients logging in often miss parts of the prompts in the tty window.