Snmp-server host, Snmp-server host (113) – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 163

Advertising
background image

Brocade 6910 Ethernet Access Switch Configuration Guide

113

53-1002581-01

SNMP Commands

6

snmp-server host

This command specifies the recipient of a Simple Network Management Protocol notification
operation. Use the no form to remove the specified host.

Syntax

snmp-server host host-addr [inform [retry retries | timeout seconds]] community-string

[version {1 | 2c | 3 {auth | noauth | priv} [udp-port port]}

no snmp-server host host-addr

host-addr - IPv4 or IPv6 address of the host (the targeted recipient). (Maximum host
addresses: 5 trap destination IP address entries)

inform - Notifications are sent as inform messages. Note that this option is only available
for version 2c and 3 hosts. (Default: traps are used)

retries - The maximum number of times to resend an inform message if the recipient
does not acknowledge receipt. (Range: 0-255; Default: 3)

seconds - The number of seconds to wait for an acknowledgment before resending an
inform message. (Range: 0-2147483647 centiseconds; Default: 1500 centiseconds)

community-string - Password-like community string sent with the notification operation to
SNMP V1 and V2c hosts. Although you can set this string using the snmp-server host
command by itself, we recommend defining it with the

snmp-server community

command

prior to using the snmp-server host command. (Maximum length: 32 characters)

version - Specifies whether to send notifications as SNMP Version 1, 2c or 3 traps.
(Range: 1, 2c, 3; Default: 1)

auth | noauth | priv - This group uses SNMPv3 with authentication, no authentication,
or with authentication and privacy. See

“Simple Network Management Protocol”

on

page 929 for further information about these authentication and encryption options.

port - Host UDP port to use. (Range: 1-65535; Default: 162)

Default Setting

Host Address: None
Notification Type: Traps
SNMP Version: 1
UDP Port: 162

Command Mode

Global Configuration

Command Usage

If you do not enter an snmp-server host command, no notifications are sent. In order to
configure the switch to send SNMP notifications, you must enter at least one snmp-server host
command. In order to enable multiple hosts, you must issue a separate snmp-server host
command for each host.

Advertising