Port Configuration

33

Command Usage

Cable diagnostics are performed using Digital Signal Processing (DSP) test methods. DSP
analyses the cable by sending a pulsed signal into the cable, and then examining the reflection
of that pulse.

Cable diagnostics can only be performed on twisted-pair media.

This cable test is only accurate for cables 7 - 140 meters long.

The test takes approximately 5 seconds. The switch displays the results of the test immediately
upon completion, including common cable failures, as well as the status and approximate
length to a fault.

Potential conditions which may be listed by the diagnostics include:

OK: Correctly terminated pair

Open: Open pair, no link partner

Short: Shorted pair

Not Supported: This message is displayed for any Gigabit Ethernet ports linked up at a
speed lower than 1000 Mbps.

Impedance mismatch: Terminating impedance is not in the reference range.

Ports are linked down while running cable diagnostics.

Parameters

These parameters are displayed:

Port – Switch port identifier.

Type – Displays media type. (GE – Gigabit Ethernet, Other – SFP)

Link Status – Shows if the port link is up or down.

Test Result – The results include common cable failures, as well as the status and approximate
distance to a fault, or the approximate cable length if no fault is found.

To ensure more accurate measurement of the length to a fault, first disable power-saving
mode on the link partner before running cable diagnostics.

For link-down ports, the reported distance to a fault is accurate to within +/- 2 meters. For
link-up ports, the accuracy is +/- 10 meters.

Last Updated – Shows the last time this port was tested.

Interface

To test the cable attached to a port:

1. Click Interface, Port, Cable Test.

2. Click Test for any port to start the cable test.