Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 588

Advertising
background image

538

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002581-01

CFM Commands

25

Default Setting

None

Command Mode

Privileged Exec

Command Usage

Use the mep keyword with this command to display the MEPs configured on this device as
DSAPs through the

ethernet cfm mep

command.

Using the mip keyword with this command to display the MIPs generated on this device by the
CFM protocol when the mip-creation method is set to either “default” or “explicit” by the

ethernet cfm domain

command or the

ma index name

command.

Example

This example shows all MEPs configured on this device for maintenance domain rd.

Console#show ethernet cfm maintenance-points local mep

MPID MD Name Level Direct VLAN Port CC Status MAC Address

---- ---------------- ----- ------ ---- -------- --------- -----------------

1 rd 0 UP 1 Eth 1/ 1 Enabled 00-12-CF-3A-A8-C0

Console#

show ethernet cfm maintenance-points local detail mep

This command displays detailed CFM information about a local MEP in the continuity check
database.

Syntax

show ethernet cfm maintenance-points local detail mep [domain domain-name |

interface interface | level level-id]

domain-name – Domain name. (Range: 1-43 alphanumeric characters)

interface – Displays CFM status for the specified interface.

ethernet unit/port

unit - Unit identifier. (Range: 1)

port - Port number. (Range: 1-12)

port-channel channel-id (Range: 1-12)

level-id – Maintenance level for this domain. (Range: 0-7)

Default Setting

None

Command Mode

Privileged Exec

Advertising