Snmp-server enable traps ethernet cfm cc, Mep archive-hold-time – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 594

Advertising
background image

544

Brocade 6910 Ethernet Access Switch Configuration Guide

53-1002581-01

CFM Commands

25

snmp-server enable traps ethernet cfm cc

This command enables SNMP traps for CFM continuity check events. Use the no form to disable
these traps.

Syntax

[no] snmp-server enable traps ethernet cfm cc [config | loop | mep-down | mep-up]

configSends a trap if this device receives a CCM with the same MPID as its own but with
a different source MAC address, indicating that a CFM configuration error exists.

loopSends a trap if this device receives a CCM with the same source MAC address and
MPID as its own, indicating that a forwarding loop exists.

mep-downSends a trap if this device loses connectivity with a remote MEP, or
connectivity has been restored to a remote MEP which has recovered from an error
condition.

mep-upSends a trap if a remote MEP is discovered and added to the local database, the
port state of a previously discovered remote MEP changes, or a CCM is received from a
remote MEP which as an expired entry in the archived database.

Default Setting

All continuity checks are enabled.

Command Mode

Global Configuration

Command Usage

All mep-up traps are suppressed when cross-checking of MEPs is enabled because cross-check
traps include more detailed status information.

Example

This example enables SNMP traps for mep-up events.

Console(config)#snmp-server enable traps ethernet cfm cc mep-up

Console(config)#

Related Commands

ethernet cfm mep crosscheck (549)

mep archive-hold-time

This command sets the time that data from a missing MEP is retained in the continuity check
message (CCM) database before being purged. Use the no form to restore the default setting.

Syntax

mep archive-hold-time hold-time

hold-time – The time to retain data for a missing MEP. (Range: 1-65535 minutes)

Advertising