Efm oam link-monitor frame, Efm oam link-monitor frame threshold – Brocade Communications Systems Brocate Ethernet Access Switch 6910 User Manual

Page 615

Advertising
background image

Brocade 6910 Ethernet Access Switch Configuration Guide

565

53-1002581-01

OAM Commands

26

Example

Console(config)#interface ethernet 1/1

Console(config-if)#efm oam critical-link-event dying-gasp

Console(config-if)#

efm oam link-monitor frame

This command enables reporting of errored frame link events. Use the no form to disable this
function.

Syntax

[no] efm oam link-monitor frame

Default Setting

Enabled

Command Mode

Interface Configuration

Command Usage

An errored frame is a frame in which one or more bits are errored.

If this feature is enabled and an errored frame link event occurs, the local OAM entity (this
switch) sends an Event Notification OAMPDU.

Example

Console(config)#interface ethernet 1/1

Console(config-if)#efm oam link-monitor frame

Console(config-if)#

efm oam link-monitor frame threshold

This command sets the threshold for errored frame link events. Use the no form to restore the
default setting.

Syntax

[no] efm oam link-monitor frame threshold count

count - The threshold for errored frame link events. (Range: 1-65535)

Default Setting

1

Command Mode

Interface Configuration

Command Usage

If this feature is enabled, an event notification message is sent if the threshold is reached or
exceeded within the period specified by the

efm oam link-monitor frame window

command

(

page 566

). The Errored Frame Event TLV includes the number of errored frames detected during

the specified period.