Brocade 6910 Ethernet Access Switch Configuration Guide

643

53-1002581-01

Navigating the Web Browser Interface

31

Configure MD

Configure Maintenance Domains

977

Add

Defines a portion of the network for which connectivity faults can
be managed, identified by an MD index, maintenance level, and the MIP
creation method

977

Configure Details

Configures the archive hold time and fault notification settings

977

Show

Shows list of configured maintenance domains

977

Configure MA

Configure Maintenance Associations

981

Add

Defines a unique CFM service instance, identified by its parent MD, the
MA index, the VLAN assigned to the MA, and the MIP creation method

981

Configure Details

Configures detailed settings, including continuity check status and
interval level, cross-check status, and alarm indication signal parameters

981

Show

Shows list of configured maintenance associations

981

Configure MEP

Configures Maintenance End Points

985

Add

Configures MEPs at the domain boundary to provide management access
for each maintenance association

985

Show

Shows list of configured maintenance end points

985

Configure Remote MEP

Configures Remote Maintenance End Points

986

Add

Configures a static list of remote MEPs for comparison against
the MEPs learned through continuity check messages

986

Show

Shows list of configured remote maintenance end points

986

Transmit Link Trace

Sends link trace messages to isolate connectivity faults by
tracing the path through a network to the designated target node

988

Transmit Loopback

Sends loopback messages to isolate connectivity faults by requesting a
target node to echo the message back to the source

989

Transmit Delay Measure

Sends periodic delay-measure requests to a specified MEP within a
maintenance association

991

Show Information

Show Local MEP

Shows the MEPs configured on this device

993

Show Local MEP Details

Displays detailed CFM information about a specified local MEP in the
continuity check database

994

Show Local MIP

Shows the MIPs on this device discovered by the CFM protocol

996

Show Remote MEP

Shows MEPs located on other devices which have been discovered
through continuity check messages, or statically configured in the MEP
database

997

Show Remote MEP Details

Displays detailed CFM information about a specified remote MEP in the
continuity check database

998

Show Link Trace Cache

Shows information about link trace operations launched from this device

999

Show Fault Notification Generator

Displays configuration settings for the fault notification generator

1001

Show Continuity Check Error

Displays CFM continuity check errors logged on this device

1002

TABLE 151

Switch Main Menu (Continued)

Menu

Description

Page

Advertising