JLG G5-18A Service Manual User Manual

Page 158

Advertising
background image

Electrical System

9-38

G5-18A, 2505H, 25.5

Seat Switch
Disagreement

23119

This fault can only occur if
the machine detects itself to
be a Tier 4 configuration.
Disagreement between seat
switch inputs is present
for 5 seconds

N/A

Latched. Check wiring to
Pins J2-7 on Ground
and Remote
IO modules

Ground Module
Parameters not
Received from
Power Module

6643

This fault can only occur if
the machine detects itself to
be a Tier 4 configuration.
startup delay of 1500ms has
expired and has not received
parameters from the Power
Module

Default machine to LSI
Cutout (if not in passive
mode or not in LSI
calibration mode) with
operation only available via
LSI Override switch (Creep
Mode operation)
This fault shall suppress
DTC 9924 from being set

Not Latched

Help Message

DTC

Trigger / Possible

Symptom

Actions

Latch / Reset

Condition