9-43

G5-18A, 2505H, 25.5

Electrical System

457

975

3

Fan actuator (PWM output); short circuit to battery

458

975

4

Fan actuator (PWM output); short circuit to ground

460

1639

0

Sensor error fan speed; signal range check high

461

1639

1

Sensor error fan speed; signal range check low

462

523602

0

High fan speed; warning threshold exceeded

463

523602

0

High fan speed; shut off threshold exceeded

464

97

3

Sensor error water in fuel; signal range check high

465

97

4

Sensor error water in fuel; signal range check low

472

94

3

Sensor error low fuel pressure; signal range check high

473

94

4

Sensor error low fuel pressure; signal range check low

474

94

1

Low fuel pressure; warning threshold exceeded

475

94

1

Low fuel pressure; shut off threshold exceeded

481

174

0

High low fuel temperature; warning threshold exceeded

482

174

0

High Low fuel temperature; shut off threshold exceeded

488

523619

2

Physical range check high for exhaust gas temperature up stream (SCR-CAT)

500

523915

0

HCI dosing valve (DV1); over current at the end of the injection phase

501

523915

12

HCI dosing valve (DV1); powerstage over temperature

502

523915

3

HCI dosing valve (DV1); short circuit to battery

503

523915

3

HCI dosing valve (DV1); short circuit to battery high side

504

523915

4

HCI dosing valve (DV1); short circuit to ground

505

523915

11

HCI dosing valve (DV1); short circuit high side powerstage

506

523916

2

Sensor HCI dosing valve (DV1) downstream pressure; plausibility error

508

523916

0

Physical range check high for HCI dosing valve (DV1) downstream pressure; shut
off regeneration

511

523916

1

Physical range check low for HCI dosing valve (DV1) downstream pressure; shut off
regeneration

514

523916

3

Sensor error HCI dosing valve (DV1) downstream pressure; signal range check high

515

523916

4

Sensor error HCI dosing valve (DV1) downstream pressure; signal range check low

516

523917

2

Sensor DV1 & DV2 upstream pressure; plausibility error

518

523917

0

Physical range check high for DV1 & DV2 upstream pressure;
shut off regeneration

521

523917

1

Physical range check low for DV1 & DV2 upstream pressure;
shut off regeneration

524

523917

3

Sensor error DV1 & DV2 upstream pressure; signal range check high

525

523917

4

Sensor error DV1 & DV2 upstream pressure; signal range check low

526

523918

2

Sensor DV1 & DV2 upstream temperature; plausibility error

528

523918

0

Physical range check high for DV1 & DV2 upstream temperature;
shut off regeneration

531

523918

1

Physical range check low for DV1 & DV2 upstream temperature; shut off
regeneration

534

523918

3

Sensor error DV1 & DV2 upstream temperature; signal range check high

535

523918

4

Sensor error DV1 & DV2 upstream temperature; signal range check low

543

676

11

Cold start aid relay error.

544

676

11

Cold start aid relay open load