3224

2

DLC Error of CAN-Receive-Frame AT1IG1 NOX Sensor (SCR-system upstream
cat; DPF-system downstream cat); length of frame incorrect

128

3224

9

Time out Error of CAN-Receive-Frame AT1IG1; NOX sensor upstream

129

3224

2

DLC Error of CAN-Receive-Frame ATllGlVol NOX Sensor (SCR-system upstream
cat; DPF-system downstream cat); length of frame incorrect

130

3224

9

Time out Error of CAN-Receive-Frame ATllGlVol; NOX sensor (SCR-system
upstream cat; DPF-system downstream cat)

133

523938

9

Time out Error (BAM to packet) for CAN-Receive-Frame ATllGCVoll information;
factors & Sensor calibration for NOX Sensor (SCR-system upstream cat; DPF-
system downstream cat)

134

523939

9

Time out Error (BAM to BAM) for CAN-Receive-Frame ATllGCVoll information;
factors & Sensor calibration for NOX Sensor (SCR-system upstream cat; DPF-
system downstream cat)

135

523940

9

Time out Error (PCK2PCK) for CAN-Receive-Frame ATllGCVoll information; factors
& Sensor calibration for NOX Sensor (SCR-system upstream cat; DPF-system
downstream cat)

137

3234

9

Time out Error of CAN-Receive-Frame AT1OG1; NOX sensor (SCR-system
downstream cat; DPF system downstream cat)

138

3234

2

DLC Error of CAN-Receive-Frame ATlOlVol NOX Sensor (SCR-system
downstream cat; DPF-system downstream cat); length of frame incorrect

139

3234

9

Time out Error of CAN-Receive-Frame ATlOGlVol; NOX sensor (SCR-system
downstream cat; DPF-system downstream cat)

140

523941

9

Time out Error (BAM to packet) for CAN-Receive-Frame ATlOGCVol2 information;
factors & Sensor calibration for NOX Sensor (SCR-system downstream cat; DPF-
system downstream cat)

141

523942

9

Time out Error (BAM to BAM) for CAN-Receive-Frame ATlOGCVol2 information;
factors & Sensor calibration for NOX Sensor (SCR-system downstream cat; DPF-
system downstream cat)

142

523943

9

Time out Error (PCK2PCK) for CAN-Receive-Frame ATlOGCVol2 information;
factors & Sensor calibration for NOX Sensor (SCR-system downstream cat; DPF-
system downstream cat)

168

523935

12

Time out Error of CAN-Transmit-Frame EEC3VOL1; Engine send messages

169

523936

12

Time out Error of CAN-Transmit-Frame EEC3VOL2; Engine send messages

171

523212

9

Time out Error of CAN-Receive-Frame ComEngPrt; Engine Protection

179

523240

9

Time out CAN-message FunModCtl; Function Mode Control

198

523216

9

Time out Error of CAN-Receive-Frame PrHtEnCmd; pre-heat
command, engine command

202

523793

9

Time out Error of CAN-Receive-Frame UAA10; AGS sensor
service message

203

523794

9

Time out Error of CAN-Receive-Frame UAA11; AGS sensor data

212

523803

9

Time out Error of CAN-Receive-Frame RxEngPres; Status burner air pump

281

523766

9

Time out Error of CAN-Receive-Frame Active TSC1AE

282

523767

9

Time out Error of CAN-Receive-Frame Passive TSC1AE

283

523768

9

Time out Error of CAN-Receive-Frame Active TSC1AR

284

523769

9

Time out Error of CAN-Receive-Frame Passive TSC1AR

285

523770

9

Time out Error of CAN-Receive-Frame Passive TSC1DE

291

523776

9

Time out Error of CAN-Receive-Frame TSC1TE - active