JLG G5-18A Service Manual User Manual

Page 160

Advertising
background image

Electrical System

9-40

G5-18A, 2505H, 25.5

75

523913

4

Sensor error glow plug control diagnostic line voltage; signal range
check low

76

523914

5

Glow plug control; open load

77

523914

12

Glow plug control; powerstage over temperature

78

523914

3

Glow plug control; short circuit to battery

79

523914

4

Glow plug control; short circuit to ground

82

1235

14

CAN Bus error passive; warning CAN C

84

639

14

CAN-Bus 0 "BusOff-Status"

85

1231

14

CAN-Bus 1 "BusOff-Status"

86

1235

14

CAN-Bus 2 "BusOff-Status"

88

102

2

Charged air pressure above warning threshold

89

102

2

Charged air pressure above shut off threshold

96

110

3

Sensor error coolant temperature; signal range check high

97

110

4

Sensor error coolant temperature; signal range check low

98

110

0

High coolant temperature; warning threshold exceeded

99

110

0

High coolant temperature; shut off threshold exceeded

101

111

1

Coolant level too low

109

523929

0

Fuel Balance Control integrator injector 1 (in firing order); maximum
value exceeded

110

523930

0

Fuel Balance Control integrator injector 2 (in firing order); maximum
value exceeded

111

523931

0

Fuel Balance Control integrator injector 3 (in firing order); maximum
value exceeded

112

523932

0

Fuel Balance Control integrator injector 4 (in firing order); maximum
value exceeded

113

523933

0

Fuel Balance Control integrator injector 5 (in firing order); maximum
value exceeded

114

523934

0

Fuel Balance Control integrator injector 6 (in firing order); maximum
value exceeded

115

523929

1

Fuel Balance Control integrator injector 1 (in firing order); minimum
value exceeded

116

523930

1

Fuel Balance Control integrator injector 2 (in firing order); minimum
value exceeded

117

523931

1

Fuel Balance Control integrator injector 3 (in firing order); minimum
value exceeded

118

523932

1

Fuel Balance Control integrator injector 4 (in firing order); minimum
value exceeded

119

523933

1

Fuel Balance Control integrator injector 5 (in firing order); minimum
value exceeded

120

523934

1

Fuel Balance Control integrator injector 6 (in firing order); minimum
value exceeded

121

1109

2

Engine shut off demand ignored

122

523698

11

Shut off request from supervisory monitoring function

125

523717

12

Time out Error of CAN-Transmit-Frame AmbCon; Weather environments

126

523603

9

Time out Error of CAN-Receive-Frame AMB; Ambient Temperature Sensor

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description

Advertising
This manual is related to the following products: