9-55

G5-18A, 2505H, 25.5

Electrical System

1410

3248

1

Physical range check low for exhaust gas temperature particulate filter downstream;
warning

1411

1188

11

Wastegate actuator; internal error

1412

1188

11

Wastegate actuator; EOL calibration not performed correctly

1413

1188

13

Wastegate actuator calibration deviation too large, re-calibration required

1414

1188

2

Wastegate; status message from ECU missing

1415

1188

7

Wastegate actuator; blocked

1416

1188

11

Wastegate actuator; over temperature (> 145°C]

1417

1188

11

Wastegate actuator; over temperature (> 135°C]

1418

1188

11

Wastegate actuator; operating voltage error

1419

524011

0

Zero fuel calibration injector 7 (in firing order); maximum value exceeded

1420

524012

0

Zero fuel calibration injector 8 (in firing order); maximum value exceeded

1421

524011

1

Zero fuel calibration injector 7 (in firing order); minimum value exceeded

1422

524012

1

Zero fuel calibration injector 8 (in firing order); minimum value exceeded

1431

524028

2

CAN message PROEGRActr; plausibility error

1432

524029

2

Time out Error of CAN-Receive-Frame ComEGRActr - exhaust gas recirculation
positioner

1436

524034

5

Disc Separator; open load

1437

524034

12

Disc Separator; power stage over temperature

1438

524034

3

Disc separator; short circuit to battery

1439

524034

4

Disc separator; short circuit to ground

1440

524030

7

EGR actuator; internal error

1441

524031

13

EGR actuator; calibration error

1442

524032

2

EGR actuator; status message "EGRCust" is missing

1443

524033

7

EGR actuator; due to overload in Save Mode

1444

2621

5

Flush valve burner (EPV DPF-System); open load

1445

2621

12

Flush valve burner (EPV DPF-System); powerstage over temperature

1446

2621

3

Flush valve burner (EPV DPF-System); short circuit to battery

1447

2621

4

Flush valve burner (EPV DPF-System); short circuit to ground

1448

175

0

High customer oil temperature; warning threshold exceeded

1449

175

0

High customer oil temperature; shut off threshold exceeded

1453

411

0

Differential pressure Venturi unit (EGR); warning threshold exceeded

1454

411

1

Differential pressure Venturi unit (EGR); shut off threshold exceeded

1455

3711

12

Regeneration temperature (PFItRgn LigtOff) not reached;
regeneration aborted

1457

524055

4

Spark Plug Control Unit (SPCU); short circuit to ground

1458

523960

0

High exhaust gas temperature EGR cooler downstream; warning
threshold exceeded

1459

523960

1

High exhaust gas temperature EGR cooler downstream; shut off
threshold exceeded

1460

1180

0

Turbocharger Wastegate CAN feedback; warning threshold exceeded

1460

1180

0

Turbocharger Wastegate CAN feedback; warning threshold exceeded

1461

1180

1

Turbocharger Wastegate CAN feedback; shut off threshold exceeded

1461

1180

1

Turbocharger Wastegate CAN feedback; shut off threshold exceeded

1462

1180

0

Exhaust gas temperature upstream turbine; warning threshold exceeded

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description