JLG G5-18A Service Manual User Manual

Page 167

Advertising
background image

9-47

G5-18A, 2505H, 25.5

Electrical System

846

523452

2

Multiple Stage Switch engine torque limitation curve; plausibility error

849

1176

3

Sensor error pressure sensor upstream turbine; signal range check high

850

1176

4

Sensor error pressure sensor downstream turbine; signal range check high

856

523613

0

Maximum positive deviation of rail pressure exceeded (RailMeUnO)

857

523613

0

Maximum positive deviation of rail pressure in metering unit
exceeded (RailMeUnl)

858

523613

0

Rail system leakage detected (RailMeUnlO)

859

523613

0

Maximum negative deviation of rail pressure in metering unit
exceeded (RailMeUn2)

860

523613

0

Negative deviation of rail pressure second stage (RailMeUn22)

861

523613

1

Minimum rail pressure exceeded (RailMeUn3)

862

523613

0

Maximum rail pressure exceeded (RailMeUn4)

864

523613

2

Set point of metering unit in overrun mode not plausible

876

523470

7

Maximum rail pressure in limp home mode exceeded (PRV)

877

157

3

Sensor error rail pressure; signal range check high

878

157

4

Sensor error rail pressure; signal range check low

881

523633

11

Nox conversion rate insufficient (SCR-Cat defect, bad AdBlue quality)

882

523633

11

Nox conversion rate insufficient (SCR-Cat defect, bad AdBlue quality); temperature
range 1

883

523633

11

Nox conversion rate insufficient (SCR-Cat defect, bad AdBlue quality); temperature
range 2

887

3234

11

Nox Sensor downstream of SCR Catalysator; plausibility error "stuck in range"

889

3224

1

Nox sensor upstream of SCR Catalysator; low signal not plausible

892

4345

11

Sensor back flow line pressure (SCR); plausibility error

893

4343

11

General pressure check error (SCR)

894

4374

13

Pressure stabilization error dosing valve (SCR)

896

523723

11

Detection of AdBlue filled SCR system in Init-State

897

523632

16

Pump pressure SCR metering unit too high

898

523632

18

Pump pressure SCR metering unit too low

899

523632

0

Pressure overload of SCR-System

900

523632

1

Pressure build-up error SCR-System

903

4365

0

Urea tank temperature too high

905

3241

0

Sensor SCR catalyst upstream temperature too high; plausibility error

906

3241

1

Sensor SCR catalyst upstream temperature too low; plausibility error

908

3361

7

AdBlue dosing valve blocked (SCR)

914

523720

2

Sensor urea supply module heater temperature; plausibility error
(normal condition)

915

523720

2

Sensor urea supply module heater temperature; plausibility error
(cold start condition)

916

523721

2

Sensor urea supply module temperature; plausibility error (normal condition)

917

523721

2

Sensor urea supply module temperature; plausibility error
(cold start condition)

918

523981

11

Urea-tank without heating function (heating phase)

919

523330

14

Immobilizer status; fuel blocked

925

523720

8

Urea supply module heater temperature; duty cycle in failure range

Fault