1068

1180

4

Sensor error exhaust gas temperature upstream turbine; signal range
check low

1069

4360

0

Physical range check high for urea catalyst upstream temperature

1070

4360

1

Physical range low for urea catalyst upstream temperature

1072

4360

3

Sensor error urea catalyst exhaust gas temperature upstream; signal range check
high

1073

4360

4

Sensor error urea catalyst exhaust gas temperature upstream; signal range check
low

1074

1761

14

Urea tank level; warning threshold exceeded

1077

3361

3

Urea dosing valve; short circuit to battery on high side

1078

3361

3

Urea dosing valve; short circuit to battery or open load on high side

1079

3361

4

Urea dosing valve; short circuit to ground or open load on low side

1080

3361

4

Urea dosing valve; short circuit on high side

1081

4345

5

SCR heater relay urea return line secondary side; open load

1082

4366

5

SCR main relay (secondary side); open load

1083

4343

5

SCR heater relay urea pressure line secondary side; open load

1084

4366

5

SCR main relay (secondary side); Shortcut to battery

1085

4366

5

SCR main relay (secondary side); shortcut to ground

1086

4341

5

SCR heater relay urea supply line secondary side; open load

1087

523719

5

SCR heater relay urea supply module secondary side; open load

1088

4366

5

SCR Tank heating valve secondary side; open load

1089

4243

11

SCR system heater diagnostic reports error; shut off SCR-system

1090

4345

5

SCR heater relay urea return line primary side; open load

1092

4345

3

SCR heater urea return line; short circuit to battery

1093

4345

4

SCR heater urea return line; short circuit to ground

1094

4343

5

SCR heater relay urea pressure line primary side; open load

1096

4343

3

SCR heater urea pressure line; short circuit to battery

1097

4343

4

SCR heater urea pressure line; short circuit to ground

1098

523718

5

SCR main relay (primary side); open load

1099

523718

12

SCR main relay (primary side); powerstage over temperature

1100

523718

3

SCR main relay (primary side); short circuit to battery

1101

523718

4

SCR main relay (primary side); short circuit to ground

1102

4341

5

SCR heater relay urea supply line primary side; open load

1104

4341

3

SCR-heater urea supply line; short circuit to battery

1105

4341

4

SCR-heater urea supply line; short circuit to ground

1106

523719

5

SCR heater relay urea supply module primary side; open load

1108

523719

3

SCR heater urea supply module; short circuit to battery

1109

523719

4

SCR heater urea supply module; short circuit to ground

1110

4366

5

SCR tank heating valve primary side; open load

1111

4366

12

SCR-heater relay urea tank powerstage output; over temperature

1112

4366

3

SCR Tank heating valve; short circuit to battery

1113

4366

4

SCR Tank heating valve; short circuit to ground

1118

4375

5

Urea pump motor; open load

1120

4375

3

Urea pump motor; short circuit to battery