JLG G5-18A Service Manual User Manual

Page 172

Advertising
background image

Electrical System

9-52

G5-18A, 2505H, 25.5

1216

523914

5

Glow plug control release line; short circuit error

1217

523914

11

Glow plug control; internal error

1219

524018

14

DPF wasn't regenerated, power reduction phase 1 (manual
regeneration request)

1220

524022

14

DPF wasn't regenerated, power reduction phase 2 (manual
regeneration request)

1221

524023

14

DPF wasn't regenerated, warning condition (manual regeneration mode)

1222

190

14

Camshaft- and Crankshaft speed sensor signal not available on CAN

1223

51

5

Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); open load

1224

51

6

Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); over current

1225

51

12

Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); over temperature

1226

51

3

EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to battery (A02)

1227

51

3

EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to battery (A67)

1228

51

4

EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to ground (A02)

1229

51

4

EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to ground (A67)

1230

51

6

Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Overload by short-
circuit

1231

51

11

Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Power stage over
temperature due to high current

1232

51

4

Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Voltage
below threshold

1239

523984

3

UB6; Short circuit to battery error of actuator relay 7

1240

523985

3

UB7; Short circuit to battery error of actuator relay £

1243

523988

5

Charging lamp; open load

1244

523988

12

Charging lamp; over temperature

1245

523988

3

Charging lamp; short circuit to battery

1246

523988

4

Charging lamp; short circuit to ground

1247

524019

11

Air Pump; air lines blocked

1248

523910

9

Air Pump; CAN communication lost

1249

523910

7

Air pump; CAN communication interrupted no purge function available

1250

523910

12

Air Pump; internal error

1251

523910

0

Air Pump; power stage over temperature

1252

523910

0

Air Pump; operating voltage error

1253

523911

7

Burner dosing valve (DV2); blocked closed

1254

524014

1

Air pressure glow plug flush line; below limit

1255

524013

7

Burner operation is interrupted too often

1256

523915

7

HCI dosing valve (DV1); blocked closed

1257

523915

7

HCI dosing valve (DV1); blocked open

1258

524016

11

HFM sensor; electrical fault

1259

524016

2

Amount of air is not plausible to pump speed

1260

524016

2

Calculated amount of air is not plausible to HFM reading

1261

523910

6

Air Pump; over current

1262

523922

7

Burner Shut Off Valve; blocked closed

1263

524021

11

Burner fuel line pipe leak behind Shut Off Valve

1264

523922

7

Burner Shut Off Valve; blocked open

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description