14 engine diagnostic trouble code emr4, 1 gauge fault code display, Engine diagnostic trouble code emr4 – JLG G5-18A Service Manual User Manual

Page 159: Gauge fault code display

Advertising
background image

9-39

G5-18A, 2505H, 25.5

Electrical System

9.14

ENGINE DIAGNOSTIC TROUBLE
CODE EMR4

9.14.1

Gauge Fault Code Display

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description

1

132

11

Air flow sensor load correction factor exceeding the maximum drift limit; plausibility
error

2

132

11

Air flow sensor load correction factor exceeding drift limit; plausibility error

3

132

11

Air flow sensor low idle correction factor exceeding the maximum drift limit

4

132

11

Air flow sensor load correction factor exceeding the maximum drift limit

9

172

2

Sensor ambient air temperature; plausibility error

34

523006

3

Controller mode switch; short circuit to battery

35

523006

4

Controller mode switch; short circuit to ground

36

523923

3

UB1; Short circuit to battery error of actuator relay 1

37

523924

3

UB2; Short circuit to battery error of actuator relay 2

38

523925

3

UB3; Short circuit to battery error of actuator relay 3

39

523926

3

UB4; Short circuit to battery error of actuator relay 4

40

523927

3

UB5; Short circuit to battery error of actuator relay 5

45

168

3

Sensor error battery voltage; signal range check high

46

168

4

Sensor error battery voltage; signal range check low

47

168

2

High battery voltage; warning threshold exceeded

48

168

2

Low battery voltage; warning threshold exceeded

49

597

2

Break lever main switch and break lever redundancy switch status
not plausible

55

523910

14

Air pump doesn't achieve air mass flow set point

56

524013

7

Burner flame unintentional deleted

57

524020

14

Engine power; Not enough oxygen for regeneration

58

523911

0

Burner dosing valve (DV2); over current at the end of the injection phase

59

523911

12

Burner dosing valve (DV2); powerstage over temperature

60

523911

3

Burner dosing valve (DV2); short circuit to battery

61

523911

3

Burner dosing valve (DV2); short circuit to battery on high side

62

523911

4

Burner dosing valve (DV2); short circuit to ground

63

523911

11

Burner dosing valve (DV2); short circuit high side powerstage

64

523912

2

Burner dosing valve (DV2) downstream pressure sensor; plausibility error

66

523912

0

Physical range check high for burner dosing valve (DV2) downstream pressure; shut
off regeneration

69

523912

1

Physical range check low for burner dosing valve (DV2) downstream pressure; shut
off regeneration. When burner injector is actuated, the measured pressure does not
rise above ca. 1250mbarabs
(expected; ca. 2400mbar).

72

523912

3

Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check high

73

523912

4

Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
check low

74

523913

3

Sensor error glow plug control diagnostic line voltage; signal range
check high

Advertising
This manual is related to the following products: