JLG G5-18A Service Manual User Manual

Page 171

Advertising
background image

9-51

G5-18A, 2505H, 25.5

Electrical System

1121

4375

4

Urea pump motor; short circuit to ground

1122

4334

0

Physical range check high for Urea Pump Pressure

1123

4334

1

Physical range check low for Urea Pump Pressure

1124

4334

0

Urea pump pressure sensor; high signal not plausible

1125

4334

1

Urea pump pressure sensor; low signal not plausible

1127

4334

3

Sensor error urea pump pressure; signal range check high

1128

4334

4

Sensor error urea pump pressure; signal range check low

1129

4376

5

SCR reversing valve; open load

1130

4376

12

SCR reversing valve; over temperature

1131

4376

3

SCR reversing valve; short circuit to battery

1132

4376

4

SCR reversing valve; short circuit to ground

1135

3031

0

AdBlue-Tank temperature; maximum exceeded

1136

3031

1

DEF-Tank temperature; below minimum

1138

3031

3

Sensor error urea tank temperature; short circuit to battery

1139

3031

4

Sensor error urea tank temperature; short circuit to ground

1157

97

12

Water in fuel level prefilter; maximum value exceeded

1158

523946

0

Zero fuel calibration injector 1 (in firing order); maximum value exceeded

1159

523947

0

Zero fuel calibration injector 2 (in firing order); maximum value exceeded

1160

523948

0

Zero fuel calibration injector 3 (in firing order); maximum value exceeded

1161

523949

0

Zero fuel calibration injector 4 (in firing order); maximum value exceeded

1162

523950

0

Zero fuel calibration injector 5 (in firing order); maximum value exceeded

1163

523951

0

Zero fuel calibration injector 6 (in firing order); maximum value exceeded

1164

523946

1

Zero fuel calibration injector 1 (in firing order); minimum value exceeded

1165

523947

1

Zero fuel calibration injector 2 (in firing order); minimum value exceeded

1166

523948

1

Zero fuel calibration injector 3 (in firing order); minimum value exceeded

1167

523949

1

Zero fuel calibration injector 4 (in firing order); minimum value exceeded

1168

523950

1

Zero fuel calibration injector 5 (in firing order); minimum value exceeded

1169

523951

1

Zero fuel calibration injector 6 (in firing order); minimum value exceeded

1170

523612

12

Internal software error ECU

1171

175

2

Customer oil temperature; signal un-plausible

1173

523973

14

SCR Tamper detection; derating timer below limit 1

1174

523974

14

SCR Tamper detection; derating timer below limit 2

1175

523975

14

Urea quality; derating timer below limit 1

1176

523976

14

Urea quality; derating timer below limit 2

1177

523977

14

Urea tank level; derating timer below limit 1

1178

523978

14

Urea tank level; derating timer below limit 2

1180

168

0

Physical range check high for battery voltage

1181

168

1

Physical range check low for battery voltage

1182

172

0

Physical range check high for intake air temperature

1183

172

1

Physical range check low for intake air temperature

1187

523980

14

Bad quality of reduction agent detected

1192

523922

12

Over temperature error on burner shut of valve

1193

1180

0

Physical range check high for exhaust gas temperature upstream turbine

1194

1180

1

Physical range check low for exhaust gas temperature upstream turbine

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description

Advertising
This manual is related to the following products: