Gold Drum (D-Sub Connectors) Installation Guide

MAN-G-DRUM(DTYPE)IG-EC (Ver. 1.400)

||VL Logic Supply(P2)|

www.elmomc.com

28

Table of Contents

9.7. VL Logic Supply(P2)

Connect the VL Logic power supply as described below.
To connect the VL Logic supply:
1.

Use a 24 – 26 AWG twisted pair shielded cable. The shield should have braid and Drain wire.

2.

The source of the VL supply must be isolated from the Mains.

3.

Before applying power, first verify that the polarity of the connection is correct.

Figure 13: VL Logic Supply Connection Diagram

9.7.1.

VL Logic Supply(P2)

Pins

Signal

Function

Cable

7, 8

VL+

Positive input terminal of the logic (Control
& Encoders) power supply

VL Logic Supply Cable

9, 18

VL-

Negative (-) terminal of logic power supply VL Logic Supply Cable

Table 3: VL Logic Supply Pins and Polarity