How to use the charts – ElmoMC Gold Line Digital Servo Drives-Gold Drum Ver 1_400 D-Sub connectors User Manual

Page 65

Advertising
background image

Gold Drum (D-Sub Connectors) Installation Guide

MAN-G-DRUM(DTYPE)IG-EC (Ver. 1.400)

||How to Use the Charts|

www.elmomc.com

65

Table of Contents

11.3. How to Use the Charts

The charts above are based upon theoretical worst-case conditions. Actual test results show 30% to
50% better power dissipation.

To determine if your application needs a heat sink:
1.

Allow maximum heat sink temperature to be 80 °C or less (shunt down is 6 °C to 8 °C higher).

4.

Determine the ambient operating temperature of the Drum as ≤ 40 °C.

5.

Calculate the allowable temperature increase according to the following example: For an

ambient temperature of 40 °C, ΔT = 80 °C to 40 °C = 40 °C

6.

Use the chart to find the actual dissipation power of the drive. Follow the voltage curve to the

desired output current and then find the dissipated power.

7.

If the dissipated power is below 12W the Drum needs no additional cooling.

Note:

The chart above shows that no heat sink is necessary when the heat sink temperature is

80 °C, ambient temperature is 40 °C and heat dissipated is 12 W.

Power Dissipation 200V series

0

50

100

150

200

250

0

6.7

13.3 20.0 26.7 33.3 40.0 46.7 53.3 60.0

Motor's Current (Ampere)

Po

we

r D

is

sip

at

io

n (

W

)

40VDC
80VDC
120VDC
160VDC
196VDC