3.6. Connecting the Power Cables

The power connectors are located at the bottom of the DC Trombone, as follows:

3.6.1.

For S type drives

Pin

Function

Cable

Power
VP+

Positive Power input

DC Power

VN-

Negative Power input

DC Power

PE

Protective earth

DC Power

Motor

AC

DC

PE

Protective earth

Motor

Motor

M1

Motor phase

Motor

N/C

M2

Motor phase

Motor

Motor

M3

Motor phase

Motor

Motor

Auxiliary 24 VDC Backup Supply

VL-

Negative Auxiliary input

Backup Power

VL+

Positive Auxiliary input

Backup Power

Connector Location

Cable Connector

Pin Positions

Table 2: Connectors for Main DC Power, Backup supply and Motor Cable –S Type Drives