DC Trombone Installation Guide

Technical Specifications

MAN-DCTROIG (Ver. 1.601)

www.elmomc.com

72

4.4.1.

Auxiliary Supply (only for S Type Drive)

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

18 VDC to 30 VDC

Auxiliary supply input power

< 5 VA (this includes the 5 V/200 mA load for the
main encoder only)
< 7 VA (this includes the 5 V/400 mA load on the
main encoder and feedback B)

Note:

An S type drive will not be operative if not having the Aux. supply (Mandatory).

4.5. Environmental Conditions

Feature

Details

Operating ambient temperature

according to IEC60068-2-2

0 °C to 40 °C (32 °F to 104 °F)

Storage temperature

-20 °C to +85 °C ( -4 °F to +185 °F)

Maximum non-condensing humidity

according to IEC60068-2-78

95%

Maximum Operating Altitude

2,000 m (6562 feet)

Mechanical Shock

according to IEC60068-2-27

15g / 11ms Half Sine

Vibration

according to IEC60068-2-6

5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G