For non-s 400 vdc type drives – ElmoMC SimplIQ Digital Servo Drives-Trombone DC User Manual
Page 28
Advertising
![background image](/manuals/558391/28/background.png)
DC Trombone Installation Guide
Installation
MAN-DCTROIG (Ver. 1.601)
28
3.6.2.
For Non-S 400 VDC Type Drives
Pin
Function
Cable
Power
VP+
Positive Power input
DC Power
VN-
Negative Power input
DC Power
PE
Protective earth
DC Power
Motor
AC
DC
PE
Protective earth
Motor
Motor
M1
Motor phase
Motor
N/C
M2
Motor phase
Motor
Motor
M3
Motor phase
Motor
Motor
Not Used
VL-
N.C.
VL+
N.C.
Connector Location
Cable Connector
Pin Positions
Table 3: Connectors for Main DC Power and Motor Cable – in Non-S 400 VDC type drives