3.7. Feedback and Control Cable Assemblies

The DC Trombone features easy-to-use D-Sub type connections for all Control and Feedback
cables. Below are instructions and diagrams describing how to assemble those cables.

1.

Use 24, 26 or 28 AWG twisted-pair shielded cables (24 AWG cable is recommended). For

best results, the shield should have aluminum foil covered by copper braid.

2.

Use only a D-Sub connector with a metal housing.

3.

Ideally, solder the shield drain wire to the connector body as shown in Figure 12. However,

the shield may also be attached without soldering, as long as the braid shield is in tight
contact with the metal housing of the D-type connector.

4.

On the motor side connections, ground the shield to the motor chassis.

5.

On controller side connections, follow the controller manufacturer’s recommendations

concerning the shield.

Figure 12: Feedback and Control Cable Assemblies

Note:

All D-Sub type connectors, used with the DC Trombone, should be assembled in this

way.

3.7.1.

Main Feedback Cable (FEEDBACK A)

The main feedback cable is used to transfer feedback data from the motor to the drive.

The DC Trombone can accept any one of the following devices as a main feedback mechanism:

Incremental encoder only

Incremental encoder with digital Hall sensors

Digital Hall sensors only

Incremental Analog (Sine/Cosine) encoder (option)

Resolver (option)

Tachometer (option)

Potentiometer (option)

Absolute Encoder

Connector body

Drain wire

soldered to

connector body

Make sure that the

braid shield is in tight

contact with the metal

housing