FEEDBACK B on the DC Trombone has a 15-pin high density D-Sub socket.

Connect the Auxiliary Feedback cable, from the controller or other device, to FEEDBACK B using
a 15-pin, high density D-Sub plug with a metal housing. When assembling the Auxiliary
Feedback cable, follow the instructions in Section 3.7 (Feedback and Control Cable Assemblies).

Figure 22: Emulated Encoder Output on FEEDBACK B - Connection Diagram

Note:

When using digital incremental encoder as the main Feedback A, buffered main encoder
signals are conveyed through the P2-I/O connector.