Can communication – ElmoMC SimplIQ Digital Servo Drives-Trombone DC User Manual

Page 63

Advertising
background image

DC Trombone Installation Guide

Installation

MAN-DCTROIG (Ver. 1.601)

www.elmomc.com

63

Figure 28: RS-232 Connection Diagram

3.9.1.2.

CAN Communication

Notes for connecting the CAN communication cable:

Use 26 or 28 AWG twisted pair shielded cables. For best results, the shield should have

aluminum foil and covered by copper braid with a drain wire

Connect the shield to the ground of the host (PC). Usually, this connection is soldered

internally inside the connector at the PC end. You can use the drain wire to facilitate
connection.

The male RJ plug must have a shield cover.

Ensure that the shield of the cable is connected to the shield of the RJ plug. The drain wire

can be used to facilitate the connection.

Connect a termination 120-Ohms resistor at each of the two ends of the network cable.

Pin Signal

Function

Pin Positions

1 CAN_H

CAN_H bus line (dominant high)

2 CAN_L

CAN_L bus line (dominant low)

3 CAN_RET

CAN Return

4, 5 N/A

6 CAN_SHLD

Shield, connected to the RJ plug cover

7 CAN_RET

CAN Return

8 N/A

Table 14: CAN Cable - Pin Assignments