Can communication – ElmoMC SimplIQ Digital Servo Drives-Trombone DC User Manual
Page 63
![background image](/manuals/558391/63/background.png)
DC Trombone Installation Guide
Installation
MAN-DCTROIG (Ver. 1.601)
63
Figure 28: RS-232 Connection Diagram
3.9.1.2.
CAN Communication
Notes for connecting the CAN communication cable:
•
Use 26 or 28 AWG twisted pair shielded cables. For best results, the shield should have
aluminum foil and covered by copper braid with a drain wire
•
Connect the shield to the ground of the host (PC). Usually, this connection is soldered
internally inside the connector at the PC end. You can use the drain wire to facilitate
connection.
•
The male RJ plug must have a shield cover.
•
Ensure that the shield of the cable is connected to the shield of the RJ plug. The drain wire
can be used to facilitate the connection.
•
Connect a termination 120-Ohms resistor at each of the two ends of the network cable.
Pin Signal
Function
Pin Positions
1 CAN_H
CAN_H bus line (dominant high)
2 CAN_L
CAN_L bus line (dominant low)
3 CAN_RET
CAN Return
4, 5 N/A
—
6 CAN_SHLD
Shield, connected to the RJ plug cover
7 CAN_RET
CAN Return
8 N/A
—
Table 14: CAN Cable - Pin Assignments