2 connection diagram, Short setup connection diagram – Lenze E94AxHE Technology Application Positioning sequence control User Manual

Page 13

Advertising
background image

EDS94TA10060xxxx EN 1.2 - 03/2010

L

13

9400 Technology applications | Positioning sequence control

Short setup

Connection diagram

4.2

Connection diagram

[4-2]

Connection diagram

* Signal must be parameterised

L1

L2

L3

E94ASxExxxx

X100

-UG

+UG

Rb2

Rb1

U V W

X105

BD1 BD2

X107

T2

X106

M

3~

R

Y

J

2

7

X7

+

+

X5

X3

F1...F3

Z1

K1

R

B

E94AZPxxxxx

EYF...

MXI1

MXI2

X4

24E GE

X2

RFR

DO3

DO4

DO2

A1R

AO2

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

A1+

A1-

DO1

GO

24O

A2+

A2-

A1-

GA

AO1

SB

T1

GI

R

B

F4

K1

O

J

I

K1

L3

PE

L2

N

L1

Quick stop

Reference switch

Enable controller

Start/back to start position

Stop positioning program

Lower table

Speed override

Positive travel range limit switch

Negative travel range limit switch

Drive ready

Max. number of sheets reached*

Error active

Homing completed (start position)*

Reset positioning program

Acceleration override

Advertising