Lenze E94AxHE Technology Application Positioning sequence control User Manual
Page 37
Advertising
EDS94TA10060xxxx EN 1.2 - 03/2010
L
37
9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Program flow
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
Sequencer
Enable Homing
Request homing
C03160/1
Sequencer
Activate Homing
Start homing
C03160/2
DIGIN 2 Home mark
C03160/3
FALSE Set home position
C03160/4
FALSE Reset home position
C03160/5
Zero position Home position
C03163
+100 % Homing override
C03186/4