Lenze E94AxHE Technology Application Positioning sequence control User Manual

Page 58

Advertising
background image

9400 Technology applications | Positioning sequence control

Parameter setting & configuration

Limiter

58

L

EDS94TA10060xxxx EN 1.2 - 03/2010

For manual jog only
C02713

Max. manual jog distance

360.0000 unit

Limited speed 1 ... 4 (only for homing, positioning, and manual jog)
C02708/1

Limited speed 1

3600.0000 unit/s

C02710/1

Delay lim. speed 1

0.0100 unit/s

2

C02711/1

S-ramp time lim. speed 1

100 ms

C02708/2

Limited speed 2

7200.0000 unit/s

C02710/2

Delay lim. speed 2

0.0100 unit/s

2

C02711/2

S-ramp time lim. speed 2

100 ms

C02708/3

Limited speed 3

14400.0000 unit/s

C02710/3

Delay lim. speed 3

0.0100 unit/s

2

C02711/3

S-ramp time lim. speed 3

100 ms

C02708/4

Limited speed 4

28800.0000 unit/s

C02710/4

Delay lim. speed 4

0.0100 unit/s

2

C02711/4

S-ramp time lim. speed 4

100 ms

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

DIGIN 3  Positive limit switch

C03150/1

DIGIN 4  Negative limit switch

C03150/2

Parameter

Lenze setting

Value Unit