9400 Technology applications | Positioning sequence control

Short setup

Step 3: Parameterising the program flow

22

L

EDS94TA10060xxxx EN 1.2 - 03/2010

4.6.4

Program step 4: Counting the sheets

4.6.5

Program step 5: Setting the status output

Tip!
In a later step, sequence control output 1 will be connected with digital output

DO3.

Action

Comment

Parameter Setting

Count the sheets and go back to program step 3,

unless 10 sheets are reached.

Selection Action Number: 1

Counter no.: 1

Comparison function: Count <

comparison

value

Step value: 1

Comparison value: 10

Sequence step: 3

1

3
4

2

Action

Comment

Parameter Setting

Set sequence control output 1 to "1", when

maximum number of sheets (10) is reached.

Selection Action Number: 1

Output for A switching: Output 1

Signal state for A switching:

Output for B switching: Deactivated

Signal state for B switching: