9400 Technology applications | Positioning sequence control

Short setup

Step 3: Parameterising the program flow

20

L

EDS94TA10060xxxx EN 1.2 - 03/2010

4.6.1

Program step 1: Homing

The "Homing" action does not have its own parameters. The settings for homing are made

via the parameters of the basic function "Homing":

1. Select "cw_Rn_TP" as homing mode (C02640).
2. Select the position of the home switch (10 mm) as home position (C02642).
3. Select the position of the first sheet (0 mm) as home target position (C02643).
4. If necessary, adapt the profile parameters for homing to your application.

4.6.2

Program step 2: Setting counter 1 to "0"

Action

Comment
Homing with homing mark (home switch at digital input DI2), after homing, approach start position

(0 mm).

Action

Comment

Parameter Setting

Step 2: Set counter 1 to "0".

Selection Action Number: 1

Counter no.: 1

Start value: 0

0

Set

0 0