Overview of action types

Action type

Function/parameter

Homing

In order to execute a homing process, the action type "Homing" is available which activates the basic

function "Homing".

Note: The "Homing" action does not have its own parameters. The settings for homing are made via

the parameters of the basic function "Homing".

Positioning

To execute a profile, 50 actions of the "Positioning" type are available.

• The execution of the adjusted profile is only started with activated waiting function if the

sequencer input selected for the waiting function accepts the selected signal state.



Sequencer

inputs ( 40)

Parameter

Information

C04513/1...50

Profile number

Specification of the profile to be executed.

• Press the "Set up profile" button to open a dialog box to

enter the corresponding profile parameters.

• In this dialog a sequence profile can also be set.

C04511/1...50

Input for waiting

function

Sequencer input 1 ... 32 to be evaluated.

• With the default setting "0" the waiting function is

skipped and the profile execution is started immediately.

C04512/1...50

Signal state for

waiting function

Profile processing is only started when the sequencer input

to be evaluated is in this state.

C04514/1...50

Sequence step

Step inside the sequence table which will be processed after

the profile has been executed.

C04515/1...50

Watchdog time

Monitoring time within which positioning must be

completed. Otherwise, a branch to the watchdog sequence

step defined in C04516 is executed.

C04516/1...50

Watchdog

sequence step

Executed when the watchdog time has expired.

Branching

25 actions of type "Branching" are available for conditional and unconditional branches (jumps).

• A branch to the indicated step is executed when the selected sequencer input has the selected

signal state at the time of processing. If not, the sequence step is processed in the sequence

table.



Sequencer inputs ( 40)

Parameter

Information

C04530/1...25

Input for

comparison

Sequencer input 1 ... 32 to be evaluated.

• With the default setting "0" a branch to the adjusted

sequence step is executed.

C04531/1...25

Comparison

value

State in which the sequencer input to be evaluated is

compared.

C04532/1...25

Sequence step in

case of equality

If the sequencer input to be evaluated equals the

comparison value, a branch to the step set here is executed.

In case of inequality or "0" setting, the next step in the

sequence table is processed.

0

1