9400 Technology applications | Positioning sequence control

Parameter setting & configuration

Program flow

40

L

EDS94TA10060xxxx EN 1.2 - 03/2010

Example
The following example illustrates the function of the variable branch based on a program

flow which contains, among other things, two actions of the "Variable branching" type.

[5.2]

Example "Variable branch"

5.3.5

Sequencer inputs

In order to control conditional branches and the optional waiting function of some action

types during the program flow, 32 sequencer inputs of "BOOL" type.

 The sequencer inputs 1 ... 16 can be linked with the signal sources of the application or

device interfaces in the dialog level Overview L_Sequencer Program inputs via

multiplexer parameters.

 For the action types "positioning", "branching", "waiting" and "stand-by", you can

individually define for each action which of the sequencer inputs is to be called for the

corresponding function when the program is executed.

Step 12

Step 13

Step 14

Step 15

Step 16

Step 17

Action number:

C0300

2

2

= 4

C04543/

2 = 16

Action number:

C0300

3

3

= 20

C04559/

3 = 12

1

n

2

1

n

2

W jump to step number [C04543/2]

W jump to step number [C04559/3]

Note!

The sequencer input 8 in the Lenze setting is linked with the digital input DI8.