3 program flow, Parameter setting & configuration program flow – Lenze E94AxHE Technology Application Positioning sequence control User Manual

Page 32

Advertising
background image

9400 Technology applications | Positioning sequence control

Parameter setting & configuration

Program flow

32

L

EDS94TA10060xxxx EN 1.2 - 03/2010

5.3

Program flow

The program flow of the positioning sequence control is selected according to a sequence

table which can contain up to 100 references to "actions".

[5-2]

Sequence table (schematic diagram)

What is an action?

 An action comprises a clear functionality which is described with a few parameters.
 Different action types are available which serve to implement, for instance, program

branching, switching operations, waiting times and counters.

 Before every action type a defined number of actions is available which can be

individually parameterised. The parameters of the actions of the same type only differ

in the subcode.

 An action can be used in several steps if always exactly the same task is to be carried

out.

 After an action has been processed, the action in the next step of the sequence table is

automatically processed unless it is jumped to another step in the sequence table due

to a branch.

 One action can be maximally processed per computing cycle.

PositionerTable

Profiles

Override

Enable

Sequencer

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

n

t

LS_Stop

internal
status machine

Status

machine

(basic drive

functions)

Basic drive functions

M

0

-100

100 200

LS_Homing

n

t

LS_Positioner

DI7

DI6

DI5

Reset

Sequencer

input 8

DI8

Positioning sequence control

1

n

2

0

1

0

Set

0 0

1

Standby

End

3
4

2

Advertising