2 action type "homing, Action type "homing" ( 36), Parameter setting & configuration program flow – Lenze E94AxHE Technology Application Positioning sequence control User Manual

Page 36

Advertising
background image

9400 Technology applications | Positioning sequence control

Parameter setting & configuration

Program flow

36

L

EDS94TA10060xxxx EN 1.2 - 03/2010

5.3.2

Action type "Homing"

In order to execute a homing process, the action type "Homing" is available for the

sequence table which activates the basic function "Homing".

[5-3]

"Homing" (schematic diagram for limited traversing range)

 Parameter setting: Tab Application parameters  dialog level Overview Homing

Basic drive functions

0

-100

100 200

LS_Homing

DI2

Sequencer

Enable/activate
homing

Status

machine

(basic drive

functions)

M

State "homing done"

DI7

DI6

DI5

Reset

Sequencer

input 8

DI8

Positioning sequence control

Note!

The "Homing" action for the sequence table does not have its own parameters.

The settings for homing are made via the parameters of the basic function

"Homing".

Parameter

Lenze setting

Value Unit

C02528

Traversing range

Limited

C02640

Homing mode

Set home pos. directly

C02642

Home position

0.0000 unit

C02643

Homing: Target position

0.0000 unit

C02644

Homing: Speed 1

360.0000 unit/s

C02645

Homing: Acceleration 1

720.0000 unit/s

2

C02646

Homing: Speed 2

180.0000 unit/s

C02647

Homing: Acceleration 2

360.0000 unit/s

2

C02648

Homing: S-ramp time

100 ms

C02649

Homing: Torque limit

10.00 %

C02650

Homing: Blocking time

1.000 s

C02652

Ref. pos. after mains switching

Delete

C02653

Max. rot. ang. aft. mns. swtch.

180 °