12 monitfollowerror1, 13 monitfollowerror2 – Lenze E94AxHE Technology Application Positioning sequence control User Manual

Page 74

Advertising
background image

9400 Technology applications | Positioning sequence control

Parameter setting & configuration

Parameterisable function blocks

74

L

EDS94TA10060xxxx EN 1.2 - 03/2010

5.14.12

MonitFollowError1

5.14.13

MonitFollowError2

C03915

String of digits

Position unit

• Read only

C03916

-2147483647

2147483647 State

• Read only

Parameter

Possible settings

Information

Is an instance of

Function

L_LdMonitFollowError



Following error monitoring ( 54)

Parameter

Possible settings

Information

C03960

-214748.3647

unit

214748.3647 Following error at the input

• Display of the input signal

dnFollowErrorIn_p in the real unit

of the machine.

C03961

String of digits

Position unit

• Read only

C03963

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03964

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated

Is an instance of

Function

L_LdMonitFollowError



Following error monitoring ( 54)

Parameter

Possible settings

Information

C03965

-214748.3647

unit

214748.3647 Following error at the input

• Display of the input signal

dnFollowErrorIn_p in the real unit

of the machine.

C03966

String of digits

Position unit

• Read only

C03968

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03969

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated

Advertising