9400 Technology applications | Positioning sequence control

Short setup

Step 2: Parameterising the application

4.5

Step 2: Parameterising the application

For parameterising the application in the »Engineer«, use the Application parameters tab

which will be displayed by default when selecting the controller in the project view:

1. Select the mains voltage (C00173).
2. Activate automatic brake control via brake module (C02580 = "Autom. with brake

module").

3. Enter gearbox ratio as a quotient (numerator and denominator): i

1

= 12.612 = 12612/

1000
– Numerator (C02520) = 12612
– Denominator (C02521) = 1000

4. Select "Unlimited" as traversing range (C02528).
5. Click Machine parameter to change to the dialog level OverviewMachine parameter