I 2 of 5 set length 1, Default – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 135

Advertising
background image

Interleaved 2 of 5 (I 2 of 5)

Enter/Exit Programming Mode

Product Reference Guide

125

I 2 of 5 Set Length 1

This feature specifies one of the barcode lengths for

I 2 of 5 Length Control

. Length 1 is the

minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. The length includes the barcode’s check and data characters. The length can be set from
2 to 50 characters in increments of two.

Table 7

provides some examples for setting Length 1. See

page 217

for detailed instructions on

setting this feature.

Table 7. I 2 of 5 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

2 Characters

6 Characters

14 Characters

50 Characters

2

Pad with leading zeroes to

yield two digits

02

06

14

50

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT I 2 of 5 LENGTH 1 SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘2’

‘0’ and ‘6’

‘1’ and ‘4’

‘5’ AND ‘0’

6

Scan ENTER/EXIT PROGRAMMING MODE

$CI2L1

Select I 2 of 5 Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

06 = Length 1 is 6 Characters

Advertising