Keyboard interface, Wedge quiet interval, Eyboard – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 224: Nterface

Advertising
background image

References

214

WDI4600

Keyboard Interface

Wedge Quiet Interval

Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard
connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments.

This feature applies ONLY to the Keyboard Wedge interface.

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-

ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3. Go to

page 37

and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter

Prog. Mode.

4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.

5. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

, that represent

the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.

This completes the procedure to set the Wedge Quiet Interval. See

Table 32

for some examples

of how to set this feature.

Table 32. Wedge Quiet Interval Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

10ms

150ms

600ms

850ms

2

Divide by 10 (and pad with

leading zeroes)

01

15

60

85

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT WEDGE QUIET INTERVAL SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘1’

‘1’ and ‘5’

‘6’ and ‘0’

‘8’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising