212

WDI4600

Disable Character

Specifies the value of the RS-232 host command used to disable the reader.

ASCII characters or any hex value from 0 to 0xFF can be selected.

Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters. 8-bit data is
not recognized when the option

Data Bits

has been set as 7 Data Bits.

To set the value:

1. Determine the desired character or value. A setting of 0xFF indicates the Disable Charac-

ter is not used (not available).

2. Use the

ASCII Chart

on the inside back cover of this manual to find the hex equivalent

for the desired character/value.

3. Go to

page 30

and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter

Programming Mode.

4. Scan the barcode: SELECT DISABLE CHARACTER SETTING.

5. Scan the appropriate two alphanumeric characters from the keypad in

Appendix D, Key-

pad

, that represent the desired character/value in step 1 above. The second character will

cause a two-beep indication.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 30

for some examples of how to set this feature.

Table 30. Disable Character Setting Examples

STEP

ACTION

EXAMPLES

1

Desired character/value

‘d’

‘}’

‘D’

Disable Command

Not Used

2

Hex equivalent from

ASCII

Chart

0x64

0x7D

0x44

0xFF

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT DISABLE CHARACTER VALUE SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘6’ and ‘4’

‘7’ and ‘D’

‘4’ and ‘4’

‘F’ AND ‘F’

6

Scan ENTER/EXIT PROGRAMMING MODE